CHAPTER 5 [RE]
REFERENCED STANDARDS


  • This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section R106 .

    AAMAAmerican Architectural Manufacturers Association
    1827 Walden Office Square
    Suite 550
    Schaumburg, IL 60173-4268
    Standard
    reference
    number
    Title Referenced
    in code
    section number
    AAMA/WDMA/CSA
    101/I.S.2/A C440—11
    North American Fenestration Standard/
    Specifications for Windows, Doors and Unit Skylights
    R402.4.3
    ACCAAir Conditioning Contractors of America
    2800 Shirlington Road, Suite 300
    Arlington, VA 22206
    Standard
    reference
    number
    Title Referenced
    in code
    section number
    Manual J—11Residential Load Calculation Eighth EditionR403.6
    Manual S—10Residential Equipment SelectionR403.6
    ASHRAEAmerican Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    1791 Tullie Circle, NE
    Atlanta, GA 30329-2305
    Standard
    reference
    number
    TitleReferenced
    in code
    section number
    ASHRAE—2009ASHRAE Handbook of FundamentalsR402.1.4, Table R405.5.2(1)
    ASHRAE 193—2010Method of Test for Determining the Airtightness of HVAC EquipmentR403.2.2.1
    ASTMASTM International
    100 Barr Harbor Drive
    West Conshohocken, PA 19428-2859
    Standard
    reference
    number
    TitleReferenced
    in code
    section number
    E 283—04Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the SpecimenR402.4.4
    CSACanadian Standards Association
    5060 Spectrum Way
    Mississauga, Ontario, Canada L4W 5N6
    Standard
    reference
    number
    TitleReferenced
    in code
    section number
    AAMA/WDMA/CSA
    101/I.S.2/A440—11
    North American Fenestration Standard/Specification for
    Windows, Doors and Unit Skylights
    R402.4.3
    ICCInternational Code Council, Inc.
    500 New Jersey Avenue, NW
    6th Floor
    Washington, DC 20001
    Standard
    reference
    number
    TitleReferenced
    in code
    section number
    IBC—12International Building Code®R201.3, R303.2, R402.2.10
    ICC 400—12Standard on the Design and Construction of Log StructuresTable R402.4.1.1
    IFC—12International Fire Code®R201.3
    IFGC—12International Fuel Gas Code®R201.3
    IMC—12International Mechanical Code®R201.3, R403.2.2, R403.5
    IPC—12International Plumbing Code®R201.3
    IRC—12International Residential Code®R201.3, R303.2, R402.2.10, R403.2.2, R403.5
    NFRCNational Fenestration Rating Council, Inc.
    6305 Ivy Lane, Suite 140
    Greenbelt, MD 20770
    Standard
    reference
    number
    TitleReferenced
    in code
    section number
    100—2010Procedure for Determining Fenestration Products U-factors—Second EditionR303.1.3
    200—2010Procedure for Determining Fenestration Product Solar Heat Gain Coefficients and Visible Transmittance at Normal Incidence—Second EditionR303.1.3
    400—2010Procedure for Determining Fenestration Product Air Leakage—Second EditionR402.4.3
    US-FTCUnited States-Federal Trade Commission
    600 Pennsylvania Avenue NW
    Washington, DC 20580
    Standard
    reference
    number
    TitleReferenced
    in code
    section number
    CFR Title 16
    (May 31, 2005)
    R-value RuleR303.1.4
    WDMAWindow and Door Manufacturers Association
    1400 East Touhy Avenue, Suite 470
    Des Plaines, IL 60018
    Standard
    reference
    number
    TitleReferenced
    in code
    section number
    AAMA/WDMA/CSA
    101/I.S.2/A440—11
    North American Fenestration Standard/Specification for
    Windows, Doors and Unit Skylights
    R402.4.3