• CHAPTER3
    JURISDICTIONAL REQUIREMENTS

    SECTION301
    GENERAL

    301.1 Scope.

    This chapter contains requirements that are specific to and selected by the jurisdiction.

    301.1.1 Application.

    The requirements contained in this code are applicable to buildings, or portions of buildings. As indicated in Section 101.3, these buildings shall meet either the requirements of ASHRAE 189.1 or the requirements contained in this code.

    301.2 Jurisdictional

    requirements. This chapter requires that the jurisdiction indicate in Table 302.1 whether specific provisions are mandatory for all buildings regulated by this code and, where applicable, the level of compliance required. All other provisions of this code shall be mandatory as applicable.

    SECTION302
    JURISDICTIONAL REQUIREMENTS

    302.1 Requirements determined by the jurisdiction.

    The jurisdiction shall indicate the following information in Table 302.1 for inclusion in its code adopting ordinance:

    1. 1.The jurisdiction shall indicate whether requirements for residential buildings, as indicated in Exception 1 to Section 101.3, are applicable by selecting “Yes” or “No” in Table 302.1. Where “Yes” is selected, the provisions of ICC 700 shall apply and the remainder of this code shall not apply.

    2. 2.Where the jurisdiction requires enhanced energy performance for buildings designed on a performance basis, the jurisdiction shall indicate a zEPI of 46 or less in Table 302.1 for each occupancy required to have enhanced energy performance.

    3. 3.Where “Yes” or “No” boxes are provided, the jurisdiction shall check the box to indicate “Yes” where that section is to be enforced as a mandatory requirement in the jurisdiction, or “No” where that section is not to be enforced as a mandatory requirement in the jurisdiction.

    TABLE 302.1

    REQUIREMENTS DETERMINED BY THE JURISDICTION

    SectionSection Title or Description and DirectivesJurisdictional Requirements
    CHAPTER 1. SCOPE AND ADMINISTRATION
    101.3 Exception 1.1Detached one- and two-family dwellings and multiple single-family dwellings (townhouses)not more than three stories in height above grade plane with a separate means ofegress, their accessory structures, and the site or lot upon which these buildings arelocated, shall comply with ICC 700.□ Yes□ No
    101.3Exception 1.2Group R-3 residential buildings, their accessory structures, and the site or lot upon whichthese buildings are located, shall comply with ICC 700.□ Yes□ No
    101.3Exception 1.3Group R-2 and R-4 residential buildings four stories or less in height above grade plane, their accessory structures, and the site or lot upon which these buildings are located, shallcomply with ICC 700.□ Yes□ No
    CHAPTER 4. SITE DEVELOPMENT AND LAND USE
    402.2.1Flood hazard area preservation, general□ Yes□ No
    402.2.2Flood hazard area preservation, specific□ Yes□ No
    402.3Surface water protection□ Yes□ No
    402.5Conservation area□ Yes□ No
    402.6Agricultural land□ Yes□ No
    402.7Greenfield sites□ Yes□ No
    407.4.1High-occupancy vehicle parking□ Yes□ No
    407.4.2Low-emission, hybrid and electric vehicle parking□ Yes□ No
    409.1Light pollution control□ Yes□ No
    CHAPTER 5. MATERIAL RESOURCE CONSERVATION AND EFFICIENCY
    503.1Minimum percentage of waste material diverted from landfills□ 50%□ 65%□ 75%
    CHAPTER 6. ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION
    302.1, 302.1.1, 602.1zEPI of Jurisdictional Choice − The jurisdiction shall indicate a zEPI of 46 or less in each occupancy for which it intends to require enhanced energy performance.Occupancy: ______zEPI: ___________
    604.1Automated demand response infrastructure□ Yes□ No
    CHAPTER 7. WATER RESOURCE CONSERVATION, QUALITY AND EFFICIENCY
    702.6Municipal reclaimed water□ Yes□ No
    CHAPTER 8. INDOOR ENVIRONMENTAL QUALITY AND COMFORT
    804.2Post-Construction Pre-Occupancy Baseline IAQ Testing□ Yes□ No
    807.1Sound transmission and sound levels□ Yes□ No
    CHAPTER 10. EXISTING BUILDINGS
    1007.2Evaluation and certification of existing buildings and building sites□ Yes□ No
    1007.3Post-certificate of occupancy annual net energy use, energy demand, and CO2e emissions reporting□ Yes□ No

    302.1.1 zEPI of 46 or less.

    Where a zEPI of 46 or less is indicated by the jurisdiction in Table 302.1, buildings shall comply on a performance-basis in accordance with Section 601.3.1.

    Exception: Buildings less than 25,000 square feet (2323 m2) in total building floor area pursuing compliance on a prescriptive basis shall be deemed to have a zEPI of 51 and shall not be required to comply with the zEPI of Jurisdictional Choice indicated by the jurisdiction in Table 302.1.