  • EDITORIAL CHANGES – SECOND PRINTING

    Page vii: paragraph 3, line 8 now reads …visions therefore contain provisions for residential buildings four stories or greater in height. Each

    Page C-16: column 5, last line now reads …3A Coweta

    Page C-31, Section C402.1: Item 1, line 6 now reads …component performance alternative of Section C402.1.5.

    Page C-32, Section C402.1.3: line 23 now reads …shall comply with Table C402.1.4 and opaque nonswinging

    Page C-32, Section C402.1.4: last 2 lines now read …doors shall comply with Table C402.1.4 and opaque nonswinging doors shall comply with Table C402.1.3.

    Page C-33, TABLE C402.1.3: column 1, row 4 now reads …Metal buildingsb

    Page C-33, TABLE C402.1.3: column 1, row 18 now reads …Heated slabs

    Page C-35, Section C402.2.3: line 5 now reads …C402.1.3, based on framing type and construction materi-

    Page C-35, Section C402.2.3: Item 3, line 2 now reads …kJ/m2 · K).

    Page C-36, Section C402.3.1: equation notation Rinitial now reads . . Rinitial = The initial solar reflectance determined in accordance with CRRC-1 Standard.

    Page C-36, TABLE C402.3: Note a, line 2 now reads …reflectance or thermal emittance shall be assigned both a 3-year-aged solar reflectance in accordance with Section C402.3.1 and a 3-year-aged thermal

    Page C-36, TABLE C402.3: Note b now reads …Aged solar reflectance tested in accordance with ASTM C 1549, ASTM E 903 or ASTM E 1918 or CRRC-1 Standard.

    Page C-36, TABLE C402.3: Note c now reads …Aged thermal emittance tested in accordance with ASTM C 1371 or ASTM E 408 or CRRC-1 Standard.

    Page C-36, TABLE C402.4: column 9 now reads …

    8
    0.29
    0.37
    0.77
    SEWN
    0.45N
    NRNR
    NRNR
    0.50
    NR

    Page C-38, Section C402.4.3.3: Exception, line 4 now reads …requirements of Table C402.4.

    Page C-38, Section C402.5.1.1: Item 4, line 2 now reads …tion C402.5.8. Where similar objects are installed

    Page C-39, Section C402.5.4: Item 2, line 1 now reads …2. Doors and door openings required to comply with

    Page C-45, TABLE C403.2.3(3): column 1, row 12 now reads …Room air conditioners, without louvered sides

    Page C-48, TABLE C403.2.3(7): column 2, row 2 now reads …< 150 Tons

    Page C-48, TABLE C403.2.3(7): column 2, row 10 now reads …< 150 Tons

    Page C-48, TABLE C403.2.3(7): column 4, row 18 now reads …≤ 0.634 FL

    Page C-48, TABLE C403.2.3(7): column 4, row 19 now reads …≤ 0.596 IPLV

    Page C-50, TABLE C403.2.3(9): column 2, row 2 now reads …< 65,000 Btu/h

    Page C-50, TABLE C403.2.3(9): column 2, row 5 now reads …< 65,000 Btu/h

    Page C-50, TABLE C403.2.3(9): column 2, row 8 now reads …< 65,000 Btu/h

    Page C-50, TABLE C403.2.3(9): column 2, row 11 now reads …< 65,000 Btu/h

    Page C-50, TABLE C403.2.3(9): column 2, row 14 now reads …< 65,000 Btu/h

    Page C-55, Section C403.2.9.1.3: line 5 now reads …C403.2.9. In addition, ducts and plenums shall be

    Page C-55, Section 403.2.10.1 has been added.

    Page C-55, Section C403.2.12.1 title now reads …C403.2.12.1 Allowable fan motor horsepower.

    Page C-56, TABLE C403.2.1 title now reads …TABLE C403.2.10 MINIMUM PIPE INSULATION THICKNESS (in inches)a, c

    Page C-56, TABLE C403.2.1: column 2, row 2 now reads …Conductivity Btu · in./(h · ft2 · ×F)b

    Page C-56, TABLE C403.2.1: column 8, row 2 now reads …≥ 8

    Page C-61, Section C403.3: line 2 now reads …shall include either an air or water economizer complying

    Page C-61, Section C403.3: Item 2, line 2 now reads …vidual fan cooling units have a capacity of less than

    Page C-61, Section C403.3: Item 9, line 2 now reads …accordance with Section C403.4.5.

    Page C-62, TABLE C403.3.1 title now reads …TABLE C403.3.1 DX COOLING STAGE REQUIREMENTS FOR MODULATING AIRFLOW UNITS

    Page C-64, Section C403.4.1.3: line 2 now reads …systems with direct digital control of individual zones

    Page C-76, Section 405.4.2.2.1 title now reads …C405.4.2.2.1 Additional interior lighting power.

    Page C-77, Section 405.4.2.2.1: Item 2, line 6 now reads …than 1.0 w/ft2 (10.7 w/m2) of such spaces.

    Page C-77, TABLE C405.4.2(1): column 1, row 3 now reads …Convention center

    Page C-89, TABLE C407.5.1(3): Note a, line 3 now reads …Section C403.4.4, Exception 4. Supply air temperature setpoint shall be constant at the design condition.

    Page C-89, TABLE C407.5.1(3): Note e, line 11 now reads …C403.4.3.3. The heat rejection device shall be an axial fan cooling tower with two-speed fans where required in Section C403.4.3. Condenser water design

    EDITORIAL CHANGES – THIRD PRINTING

    Page C-31, Section C401.2: Item 3, line 2 now reads …C405.2, C405.3, C405.5, C405.6 and C407. The build-

    Page C-31, Section C401.2.1: line 6 now reads …Table C402.4.

    Page C-31, Section C401.2.1: Exception line 4 now reads …listed in Table C402.4 shall be permitted to satisfy the

    Page C-31, Section C401.2.1: Exception line 6 now reads …category listed in Table C402.4. Individual fenestration

    Page C-35, Section C402.2.4: Exception 1, line 7 now reads …C402.1.3 for “Metal framed” or “Wood framed

    Page C-37, Section C402.4.2: Exception 5, line 5 now reads …C405.2.3.

    Page C-37, Section C402.4.2.1: line 4 now reads …electric lights within daylight zones under skylights.

    Page C-39, Section C402.5.4: Exception 1, line 2 now reads …716 or 716.5 of the International Building Code.

    Page C-40, Section C402.5.7: Exception 6 has been renumbered as Exception 7 and a new Exception 6 now reads …Doors used primarily to facilitate vehicular movement or material handling and adjacent personnel doors.

    Page C-53, Section C403.2.6.1: line 5 now reads …of floor area (as established in Table 403.3.1.1 of the

    Page C-61, Section C403.3: Exception 2 now reads as shown:

    1. 2.In climate zones other than 1A and 1B, where individual fan cooling units have a capacity of less than 54,000 Btu/h (15.8 kW) and meet one of the following:

      1. 2.1.Have direct expansion cooling coils.

      2. 2.2.The total chilled water system capacity less the capacity of fan units with air economizers is less than the minimum specified in Table C403.3(1).

      3. The total supply capacity of all fan-cooling units not provided with economizers shall not exceed 20 percent of the total supply capacity of all fan-cooling units in the building or 300,000 Btu/h (88 kW), whichever is greater.

    Page C-75, Section C405.2.4: Exception now reads as shown:

    1. 3.Hotel and motel sleeping units and guest suites shall have a master control device that is capable of automatically switching off all installed luminaires and switched receptacles within 20 minutes after all occupants leave the room.

      Exception: Lighting and switched receptacles controlled by captive key systems.

    Page C-79, Section C405.5.1: line 5 now reads …ted in Table C405.5.1(2) for the applicable lighting zone.

    Page C-79, Section C405.5.1: line 7 now reads …tions listed in Table C405.5.1(2), in the Tradable Surfaces sec-

    Page C-79, Section C405.5.1: line 9 now reads …from Table C405.5.1(1) unless otherwise specified by the

    Page C-79, TABLE C405.5.2(1): title now reads …TABLE C405.5.1(1) EXTERIOR LIGHTING ZONES

    Page C-80, TABLE C405.5.2(2): title now reads …TABLE C405.5.1(2) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS