Browse

CHAPTER 12
REFERENCED STANDARDS


  • This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.4.

    AHRIAir Conditioning, Heating and Refrigeration Institute
    2111 Wilson Boulevard, Suite 500
    Arlington, VA 22201
    Standard
    reference
    number
    TitleReferenced
    in code
    section number
    810—2007Standard for Performance Rating of Automatic Commercial Ice-MakersTable 609.2.3
    870—2009Direct Geoexchange Heat PumpsTable 606.2.2.1
    AMCAAir Movement and Control Association International
    25 West 43rd Street
    Fourth Floor
    New York, NY 10036
    Standard
    reference
    number
    TitleReferenced
    in code
    section number
    205—10Energy Efficiency Classification for Fans606.2.2.3
    220—05Laboratory Methods of Testing Air Curtain Units for Aerodynamic Performance Rating605.1.2.3
    AITCAmerican Institute of Timber Construction
    7012 South Revere Parkway, Suite 140
    Englewood, CO 80112
    Standard
    reference
    number
    TitleReferenced
    in code
    section number
    ANSI/AITC 190.1—2007Structural Glued Laminated Timber202
    ANSIAmerican National Standards Institute
    25 West 43rd Street, Fourth Floor
    New York, NY 10036
    Standard
    reference
    number
    TitleReferenced
    in code
    section number
    Z21.50/CSA 2.22.2007Vented Gas Fireplaces804.1.3
    Z21.88a/CSA 2.33a—09ANSI/CSA Standard for Vented Gas Fireplace Heaters804.1.3
    APHAAmerican Public Health Association
    800 I Street NW
    Washington, DC 20001
    Standard
    reference
    number
    TitleReferenced
    in code
    section number
    2005Standard Methods for Examination of Water and Waste Water-21st Edition707.15.1.1
    ARBCalifornia Air Resource Board
    1001 “I“ Street, P. O. Box 2815
    Sacramento, CA 9512
    Standard
    reference
    number
    TitleReferenced
    in code
    section number
    February 1, 2008California Air Resources Board, Architectural Coatings Suggested Control Measures
    February 1, 2008
    Table 806.3(1)
    ASAAcoustical Society of America
    Suite 1N01
    2 Huntington Quadrangle
    Melville, NY 11747-4502
    Standard
    reference
    number
    TitleReferenced
    in code
    section number
    ANSI/ASA S12.60-2010/
    Pt.1
    Acoustical Performance Criteria, Design Requirements, and Guidelines for Schools,
    Part 1: Permanent Schools
    Table 807.4.3
    ANSI/ASA S12.60-2009/
    Pt.2
    Acoustical Performance Criteria, Design Requirements, and Guidelines for Schools,
    Part 2: Relocatable Classroom Factors
    Table 807.4.3
    ASABEAmerican Society of Agricultural and Biological Engineers
    2950 Niles Road
    St. Joseph, MI 49085
    Standard
    reference
    number
    TitleReferenced
    in code
    section number
    S313.3-99 (R2009)Soil Cone Penetrometer405.1.4.2
    EP542-99 (R2009)Procedures for Using and Reporting Data Obtained with the Soil Cone Penetrometer405.1.4.2
    ASHEThe American Society for Healthcare Engineering of the American Hospital Association
    155 N. Wacker Drive, Suite 400
    Chicago, IL 60606
    Standard
    reference
    number
    TitleReferenced
    in code
    section number
    2010 FGI-ASHEGuidelines for Design and Construction of Healthcare FacilitiesTable 807.3.2
    ASMEAmerican Society of Mechanical Engineers
    Three Park Avenue
    New York, NY 10016-5990
    Standard
    reference
    number
    TitleReferenced
    in code
    section number
    A112.18.1/
    CSA B125.1—2010
    Plumbing Supply FittingsTable 702.1, 702.2
    ASHRAEAmerican Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    1791 Tullie Circle
    Atlanta, GA 30329-2305
    Standard
    reference
    number
    TitleReferenced
    in code
    section number
    52.2—2007Method of Testing General Ventilation Air-Cleaning Devices for Removal
    Efficiency by Particle Size
    803.1.3, 803.5
    55—2004Thermal Environmental Conditions on Human Occupancy606.5.1, 803.2
    62.1—2010Ventilation for Acceptable Indoor Air Quality604.3
    72—05Method of Testing Commercial Refrigerators and FreezersTable 609.2.3
    90.1—2010Energy Standard for Buildings Except Low-rise Residential Buildings
    (ANSI/ASHRAE/IESNA 90.1-2007)
    602.1.2, 602.1.2.1
    189.1—2011Standard for the Design of High-performance Green Buildings,
    Except Low-rise Residential Buildings
    101.3, 301.1.1
    ASSEAmerican Society of Sanitary Engineering
    901 Canterbury Road, Suite A
    Westlake, OH 44145
    Standard
    reference
    number
    TitleReferenced
    in code
    section number
    1016—2010Performance Requirements for Automatic Compensating, Valves for Individual
    Showers and Tub/Shower Combinations
    Table 702.1
    ASTMASTM International
    100 Barr Harbor
    West Conshohocken, PA 19428-2959
    Standard
    reference
    number
    TitleReferenced
    in code
    section number
    C 1371—04aStandard Test Method for Determination of Emittance of Materials Near Room Temperature Using
    Portable Emissometers
    408.3.1.1
    C 1549—09Standard Test Method for Determination of Solar Reflectance Near Ambient Temperature
    Using a Portable Solar Reflectometer
    408.2.1, 408.3.1.1
    D 1253—08Standard Test Method for Residual Chlorine in Water707.11.6, 707.15.1.1.2, 708.12.5
    D 2974—07aStandard Test Methods for Moisture, Ash, and Organic Matter of Peat and other Organic Soils405.1.4.2
    D 3385—09Standard Test Method for Infiltration Rate of Soils in Field Using Double-Ring Infiltrometer405.1.4.2
    D 3960—05Standard Practice of Determining Volatile Organic Compound (VOC)
    Content of Paints & Related Coatings
    806.2, 806.3
    D 5055—10Standard Specification for Establishing and Monitoring Structural Capacities
    of Prefabricated Wood I-Joists
    202
    D 5093—02 (2008)Standard Test Method for Field Measurement of Infiltration Rate Using Double-Ring
    Infiltrometer With Sealed-Inner Ring
    405.1.4.2
    D 5197—09Test Method for Determination of Formaldehyde and Other Carbonyl
    Compounds in Air (Active Sampler Methodology)
    804.3
    D 5456—10Standard Specification for Evaluation of Structural Composite Lumber Products202
    D 5464—07Standard Test Method for pH Measurement of Water of Low Conductivity707.15.1.1.2
    D 5466—01 (2007)Test Method for Determination of Volatile Organic Chemicals in
    Atmospheres (Canister Sampling Methodology)
    804.2
    D 5907—10Standard Test Methods for Filterable Matter (Total Dissolved Solids) and Nonfilterable
    Matter (Total Suspended Solids) in Water
    707.15.1.1.2
    D 6007—02 (2008)Standard Test Method for Determining Formaldehyde Concentrations in Air
    from Wood Products Using a Small-Scale Chamber
    Table 806.1
    D 6196—03 (2009)Standard Practice for Selection of Sorbents, Sampling, and Thermal Desorption
    Analysis Procedures for Volatile Organic Compounds in Air
    804.3
    D 6345—10Standard Guide for Selection of Methods for Active, Integrative Sampling of
    Volatile Organic Compounds in Air
    804.3
    D 6698—07Standard Test Method for On-Line Measurement of Turbidity Below 5 NTU in Water707.15.1.1.2
    D 6866—11Standard Test Methods for Determining the Biobased Content of Solid, Liquid,
    and Gaseous Samples Using Radiocarbon Analysis
    505.2.4
    D 7612—10Standard Practice in Categorizing Wood and Wood-Based Products according to their Fiber Sources202
    E 90—04Test Method for Laboratory Measurement of Airborne Sound Transmission
    Loss of Building Partitions and Elements
    807.2, 807.3 807.4.1, 809.2, 809.3
    E 336—2010Standard Test Method for Measurement of Airborne Sound Attenuation Between Rooms in Buildings807.2
    E 408—71 (2008)Standard Test Methods for Total Normal Emittance of Surfaces Using Inspection-Meter Techniques408.3.1.1
    E 413—10Classification for Rating Sound Insulation807.4.1
    E 492—09Standard Test Method for Laboratory Measurement of Impact Sound Transmission
    Through Floor-Ceiling Assemblies Using the Tapping Machine
    807.4
    E 779—10Standard Test Method for Determining Air Leakage Rate by Ton Pressurization605.1.2.2
    E 1332—90 (2003)Standard Classification for the Determination of Outdoor-Indoor Transmission Class807.2
    E 1333—10Standard Test Method for Determining Formaldehyde Concentrations in Air and
    Emission Rates from Wood Products Using a Large Chamber
    Table 806.1
    E 1509—04Standard Specification for Room Heaters, Pellet Fuel-Burning Type804.1.6
    E 1643—10Standard Practice for Selection, Design, Installation, and Inspection of Water Vapor
    Retarders Used in Contact with Earth or Granules Fill Under Concrete Slabs
    804.2.2, Table 903.1
    E 1918—06Standard Test Method for Measuring Solar Reflectance of Horizontal and Low-Sloped
    Surfaces in the Field
    408.2.1, 408.3.1.1
    E 1980—11Standard Practice for Calculating Solar Reflectance Index of Horizontal
    and Low-Sloped Opaque Surfaces
    408.3.1.2
    E 2399—11Standard Test Method for Maximum Media Density for Dead Load Analysis of
    Vegetative (Green) Roof Systems
    408.3.2
    E 2635—08Standard Practice for Water Conservation in Buildings Through In-Situ Water Reclamation709.9
    E 2727—10Standard Practice for Assessment of Rainwater Quality707.12.10
    F 1275—03 (2008)Standard Test Method for Performance of GriddlesTable 609.2.3
    F 1346—91 (2010)Standard Performance Specification for Safety Covers and Labeling Requirements for
    All Covers for Swimming Pools, Spas and Hot Tubs
    1003.2.5
    F 1361—07Standard Test Method for Performance of Open Deep Fat FryersTable 609.2.3
    F 1496—99 (2005)e1Standard Test Method for Performance of Convection OvensTable 609.2.3
    F 1484—05Standard Test Methods for Performance of Steam CookersTable 609.2.3
    F 1605—95 (2007)Standard Test Method for Performance of Double-Sided GriddlesTable 609.2.3
    F 1639—05Standard Test Method for Performance of Combination Ovens702.17
    F 1696—07Standard Test Method for Energy Performance of Single-Rack, Door-Type
    Commercial Dishwashing Machines
    Table 609.2.3
    F 1920—11Standard Test Method for Performance of Rack Conveyor, Commercial
    Dishwashing Machines
    Table 609.2.3
    F 2140—11Standard Test Method for Performance of Hot Food Holding CabinetsTable 609.2.3
    F 2144—09Standard Test Method for Performance of Large Open Vat FryersTable 609.2.3
    F 2861—10Standard Test Method for Enhanced Performance of Combination Oven in Various ModesTable 609.2.3
    CCRCalifornia Code of Regulations
    Department of Industrial Relations
    Office of the Director
    455 Golden Gate Avenue
    San Francisco, CA 94102
    Standard
    reference
    number
    TitleReferenced
    in code
    section number
    Section 93120—Title 17California Code Regulations, Airborne Toxic Control Measure to
    Reduce Formaldehyde Emissions from Composite Wood Products
    806.1
    CDPHCalifornia Department of Public Health
    1615 Capitol Avenue
    Sacramento, CA 95814
    Standard
    reference
    number
    TitleReferenced
    in code
    section number
    CDPH Section 01350EHLB Standard Method for Testing VOC Emissions From Indoor Sources806.2
    CRRCCool Roof Rating Council
    1610 Harrison Street
    Oakland, CA 94612
    Standard
    reference
    number
    TitleReferenced
    in code
    section number
    CRRC—1 2010Cool Roof Rating Council, CRRC-1 Standard404.3.1.1
    CSACanadian Standards Association
    5060 Spectrum Way
    Mississauga, Ontario, Canada L4N 5N6
    Standard
    reference
    number
    TitleReferenced
    in code
    section number
    CAN/CSA B366.1—2009Solid-Fuel-Fired Central Heating Appliances804.1.6
    CSA Z21.50/CSA 2.22—07Vented Gas Fireplaces804.1.3
    CSA Z21.88a/CSA 2.33a—09ANSI/CSA Standard for Vented Gas Fireplace Heaters804.1.3
    DCHSCalifornia Department of Health Services
    Office of Regulations
    P.O. Box 997413, MS 0015
    Sacramento, CA 95899-7413
    Standard
    reference
    number
    TitleReferenced
    in code
    section number
    CA/DHS/EHLB/
    R-174—2010
    Standard Method for the Testing and Evaluation of Volatile Organic Chemical
    Emissions from Indoor Sources using Environmental Chambers
    Version 1.1 February 2010
    806.2, Table 806.2(2), 806.3,
    Table 806.2(2), 806.5, 806.6, 809.2.4
    DOCU.S. Department of Commerce
    National Institute of Standards and Technology
    1401 Constitution Avenue NW
    Washington, DC 20230
    Standard
    reference
    number
    TitleReferenced
    in code
    section number
    PS1—09Structural Plywood202
    PS2—10Performance Standard for Wood-Based Structural-Use Panels202